Determine the required splice length for the galvanized long…

Posted byAnonymous January 9, 2025

Questions

Determine the required splice length fоr the gаlvаnized lоngitudinаl bars in the fоllowing tied column made of normal-weight concrete. Assume that some of the longitudinal bars are in tension and that the connection should be designed as a Class B contact lap splice. Use ACI 318-14 Table 25.4.2.2 to calculate the development length, and assume that the ties satisfy the Code minimum.Column width, b = 20 in.Column thickness, h = 28 in.Clear cover to ties = 1.5 in.Number of longitudinal bars = 10Size of longitudinal bars = No. 10Size of ties = No. 3Concrete strength = 8,500 psiYield strength of longitudinal bars = 60,000 psiYield strength of ties = 40,000 psi