Air stripping process is used as a pump and treat method for…
Air stripping process is used as a pump and treat method for removing a trichloroethylene (TCE) from groundwater. The following conditions apply: Influent flow rate = 40 m3/sec QA/QW = 20 Dimensionless Henry’s constant = 0.2 TCE concentration in the influent = 1.1 mg/L TCE concentration in the effluent = 50 µg/L The plant operator wants to operate at QA/QW = 2, this operating condition: