GradePack

    • Home
    • Blog
Skip to content
bg
bg
bg
bg

GradePack

Determine the maximum axial strength φPn,max for the followi…

Determine the maximum axial strength φPn,max for the following circular tie column.Column diameter, h = 24 in.Number of longitudinal bars = 16Size of longitudinal bars = No. 8Size of ties = No. 4Concrete strength = 6,500 psiYield strength of longitudinal bars = 60,000 psiYield strength of ties = 60,000 psi

Read Details

Determine the required splice length for the galvanized long…

Determine the required splice length for the galvanized longitudinal bars in the following tied column made of lightweight concrete. Assume that some of the longitudinal bars are in tension and that the connection should be designed as a Class B contact lap splice. Use ACI 318-14 Table 25.4.2.2 to calculate the development length, and assume that the ties satisfy the Code minimum.Column width, b = 22 in.Column thickness, h = 24 in.Clear cover to ties = 1.5 in.Number of longitudinal bars = 12Size of longitudinal bars = No. 7Size of ties = No. 3Concrete strength = 5,000 psiYield strength of longitudinal bars = 60,000 psiYield strength of ties = 40,000 psi

Read Details

Tied columns are less ductile than spiral columns, giving ti…

Tied columns are less ductile than spiral columns, giving tied columns a lower strength-reduction factor.

Read Details

ACI 318-14 Section 25.7.2.1 specifies that ties shall have a…

ACI 318-14 Section 25.7.2.1 specifies that ties shall have a center-to-center spacing not exceeding the least of 16db of longitudinal bar, 48db of tie bar, and largest dimension of member.

Read Details

Determine the maximum pitch, s, for the spirals in the follo…

Determine the maximum pitch, s, for the spirals in the following circular column.Column diameter, h = 28 in.Clear cover to spirals = 1.5 in.Number of longitudinal bars = 16Size of longitudinal bars = No. 8Size of spiral = No. 3Concrete strength = 7,500 psiYield strength of longitudinal bars = 60,000 psiYield strength of spiral = 60,000 psi

Read Details

Determine the required splice length for the galvanized long…

Determine the required splice length for the galvanized longitudinal bars in the following tied column made of lightweight concrete. Assume that some of the longitudinal bars are in tension and that the connection should be designed as a Class B contact lap splice. Use ACI 318-14 Table 25.4.2.2 to calculate the development length, and assume that the ties satisfy the Code minimum.Column width, b = 28 in.Column thickness, h = 26 in.Clear cover to ties = 1.5 in.Number of longitudinal bars = 12Size of longitudinal bars = No. 6Size of ties = No. 3Concrete strength = 5,000 psiYield strength of longitudinal bars = 60,000 psiYield strength of ties = 40,000 psi

Read Details

Determine the required splice length for the longitudinal ba…

Determine the required splice length for the longitudinal bars in the following tied column. Assume that all of the longitudinal bars are in compression and that you will use a contact lap splice. Do not incorporate a reduction in length due to ACI 318-14 Section 10.7.5.2.1.Column width, b = 20 in.Column thickness, h = 18 in.Clear cover to ties = 1.5 in.Number of longitudinal bars = 10Size of longitudinal bars = No. 8Size of ties = No. 3Concrete strength = 4,500 psiYield strength of longitudinal bars = 60,000 psiYield strength of ties = 40,000 psi

Read Details

In tall buildings, the concrete strength in the columns is o…

In tall buildings, the concrete strength in the columns is often selected to be _______ that in the floors.

Read Details

Determine the maximum axial strength φPn,max for the followi…

Determine the maximum axial strength φPn,max for the following tied column.Column width, b = 26 in.Column thickness, h = 28 in.Number of longitudinal bars = 8Size of longitudinal bars = No. 9Size of ties = No. 3Concrete strength = 5,500 psiYield strength of longitudinal bars = 60,000 psiYield strength of ties = 40,000 psi

Read Details

The strength reduction factor of compression-controlled tied…

The strength reduction factor of compression-controlled tied columns is _____.

Read Details

Posts pagination

Newer posts 1 … 26,535 26,536 26,537 26,538 26,539 … 69,303 Older posts

GradePack

  • Privacy Policy
  • Terms of Service
Top