GradePack

    • Home
    • Blog
Skip to content
bg
bg
bg
bg

GradePack

An unbraced beam-column with no moment frames has an Euler b…

An unbraced beam-column with no moment frames has an Euler buckling strength of 2,396 kips with a story shear of 4.50 kips. What is the drift index for the column?

Read Details

A W14x74 of A992 steel is to be investigated for use as a be…

A W14x74 of A992 steel is to be investigated for use as a beam-column in an unbraced frame. The length is 13 feet. First-order analyses of the frame were performed for both the sway and nonsway cases. The factored loads and moments corresponding to one of the load combinations to be investigated are given for this member in the following table. The multiplier to account for P-δ effects was determined to be 1.07, and the multiplier to account for P-Δ effects was determined to be 1.20. Determine the required second-order flexural strength, Mr, at the bottom of the member.Type of analysisPu (kips)Mtop (kip-ft)Mbottom (kip-ft)Nonsway3503520Sway1605095 

Read Details

For small axial loads, the axial load term of the correspond…

For small axial loads, the axial load term of the corresponding AISC interaction equation is slightly _______.

Read Details

A W14x82 of A992 steel is to be investigated for use as a be…

A W14x82 of A992 steel is to be investigated for use as a beam-column in an unbraced frame. The length is 14 feet. First-order analyses of the frame were performed for both the sway and nonsway cases. The factored loads and moments corresponding to one of the load combinations to be investigated are given for this member in the following table. The multiplier to account for P-δ effects was determined to be 1.11, and the multiplier to account for P-Δ effects was determined to be 1.28. Determine the required second-order flexural strength, Mr, at the top of the member.Type of analysisPu (kips)Mtop (kip-ft)Mbottom (kip-ft)Nonsway3004015Sway1803090 

Read Details

Mnt represents the maximum moment assuming that no sidesway…

Mnt represents the maximum moment assuming that no sidesway occurs.

Read Details

Most beams and columns are subjected to some degree of both…

Most beams and columns are subjected to some degree of both bending and axial load.

Read Details

A W14x68 of A992 steel is to be investigated for use as a be…

A W14x68 of A992 steel is to be investigated for use as a beam-column in an unbraced frame. The length is 15 feet. First-order analyses of the frame were performed for both the sway and nonsway cases. The factored loads and moments corresponding to one of the load combinations to be investigated are given for this member in the following table. Bending is around the strong axis. The effective length factors are Kx = 1.0 for the braced case, Kx = 1.0 for the unbraced case, and Ky = 1.0. The multiplier to account for P-δ effects was determined to be 1.05, and the multiplier to account for P-Δ effects was determined to be 1.18. Using LRFD and Cb = 1.0, determine the value of the AISC interaction equation.Type of analysisPu (kips)Mtop (kip-ft)Mbottom (kip-ft)Nonsway2903518Sway903090 

Read Details

A W14x74 of A992 steel is to be investigated for use as a be…

A W14x74 of A992 steel is to be investigated for use as a beam-column in an unbraced frame. The length is 13 feet. First-order analyses of the frame were performed for both the sway and nonsway cases. The factored loads and moments corresponding to one of the load combinations to be investigated are given for this member in the following table. The multiplier to account for P-δ effects was determined to be 1.17, and the multiplier to account for P-Δ effects was determined to be 1.21. Determine the required second-order axial strength, Pr, of the member.Type of analysisPu (kip)Mtop (kip-ft)Mbottom (kip-ft)Nonsway3504530Sway10555110 

Read Details

A W14x82 of A992 steel is to be investigated for use as a be…

A W14x82 of A992 steel is to be investigated for use as a beam-column in an unbraced frame. The length is 13 feet. First-order analyses of the frame were performed for both the sway and nonsway cases. The factored loads and moments corresponding to one of the load combinations to be investigated are given for this member in the following table. The multiplier to account for P-δ effects was determined to be 1.14, and the multiplier to account for P-Δ effects was determined to be 1.26. Determine the required second-order axial strength, Pr, of the member.Type of analysisPu (kip)Mtop (kip-ft)Mbottom (kip-ft)Nonsway3755516Sway1305595 

Read Details

A W14x74 of A992 steel is to be investigated for use as a be…

A W14x74 of A992 steel is to be investigated for use as a beam-column in an unbraced frame. The length is 15 feet. First-order analyses of the frame were performed for both the sway and nonsway cases. The factored loads and moments corresponding to one of the load combinations to be investigated are given for this member in the following table. Bending is around the strong axis. The effective length factors are Kx = 1.0 for the braced case, Kx = 1.0 for the unbraced case, and Ky = 1.0. The multiplier to account for P-δ effects was determined to be 1.18, and the multiplier to account for P-Δ effects was determined to be 1.14. Using LRFD and Cb = 1.0, determine the value of the AISC interaction equation.Type of analysisPu (kips)Mtop (kip-ft)Mbottom (kip-ft)Nonsway4003526Sway604590 

Read Details

Posts pagination

Newer posts 1 … 31,582 31,583 31,584 31,585 31,586 … 64,000 Older posts

GradePack

  • Privacy Policy
  • Terms of Service
Top