GradePack

    • Home
    • Blog
Skip to content
bg
bg
bg
bg

GradePack

Map cracking can be prevented by proper mix design and by pr…

Map cracking can be prevented by proper mix design and by preventing rapid drying of the surface during the first hour or so after placing.

Read Details

Bricks expand with time due to an increase in _______ above…

Bricks expand with time due to an increase in _______ above their kiln-dried condition.

Read Details

What is the easiest way to test the bond strength of bars in…

What is the easiest way to test the bond strength of bars in a laboratory?

Read Details

The actual size of a hook in a hooked anchorage is frequentl…

The actual size of a hook in a hooked anchorage is frequently critical in detailing a structure.

Read Details

There are no ACI Code requirements placed on structural inte…

There are no ACI Code requirements placed on structural integrity of cast-in-place reinforced concrete construction, precast construction, and prestressed concrete slabs.

Read Details

Determine the size modification factor, ψs, for a rectangula…

Determine the size modification factor, ψs, for a rectangular beam with b = 17 in. and d = 21 in., five uncoated No. 7 Grade 60 tension-reinforcement bars placed in the bottom of the beam, and No. 4 Grade 40 stirrups located every 10 in. along the span. Assume 8,000-psi lightweight concrete and a clear cover of 1.75 in.

Read Details

Bricks expand with time due to an increase in _______ above…

Bricks expand with time due to an increase in _______ above their kiln-dried condition.

Read Details

Determine the epoxy modification factor, ψe, for a rectangul…

Determine the epoxy modification factor, ψe, for a rectangular beam with b = 17 in. and d = 22 in., five epoxy-coated No. 8 Grade 60 tension-reinforcement bars placed in the top of the beam, and No. 3 Grade 40 stirrups located every 10 in. along the span. Assume 4,000-psi normal-weight concrete and a clear cover of 2 in.

Read Details

In a pull-out test, a concrete cylinder containing the bar i…

In a pull-out test, a concrete cylinder containing the bar is placed on a stiff plate and a jack is used to push the bar into the cylinder.

Read Details

There are no ACI Code requirements placed on structural inte…

There are no ACI Code requirements placed on structural integrity of cast-in-place reinforced concrete construction, precast construction, and prestressed concrete slabs.

Read Details

Posts pagination

Newer posts 1 … 35,618 35,619 35,620 35,621 35,622 … 78,415 Older posts

GradePack

  • Privacy Policy
  • Terms of Service
Top