Prоblem 2. Heаt thrоugh the wаll оf аn autoclave Metal medical instruments, glassware and media for microbial culture are usually sterilized in autoclaves. These equipment have rigid and insulated sterilization chambers where the materials are exposed to high temperatures and pressures. The wall of the sterilization chamber in an autoclave is constructed of two 2-cm-thick steel plates (k = 15 W/m·K) 10 cm apart, with the space between them filled with fiberglass insulation (k = 0.035 W/m·K). This is illustrated in the figure below. If the temperature at the inner surface of the wall is 121°C and that at the outer surface is 30°C, Determine: The heat flux through the wall, in W/m2 The temperature at the boundary of the insulation and the outer steel plate, in °C